Part Number Hot Search : 
87208 PF01411 P3V6FB1 B1010 RF3866 D1004 AM29LV L20PF
Product Description
Full Text Search
 

To Download HTS10-P Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 HTS 10-P Current Transducer
The HTS 10-P provides electronic measurement of AC, DC, pulsed, and complex currents with galvanic isolation between the primary (power) circuit and the secondary (measurement) circuit.
Electrical Data Nominal Current Measurement Range Sensitivity @ 25C (note 1) Overload Capacity Supply Voltage (note 1) Primary to Secondary Isolation Maximum Output (note 2) Accuracy-Dynamic Performances Zero Offset @25C (note 1) Linearity @ 25C Zero Offset Drift Magnetic Offset Gain Drift Bandwidth, typical Response Time, typical General Data Operating Temperature Storage Temperature Current Consumption Output Current (note 3) Enclosure and Potting Weight Fastening Output Reference Notes: 1) This device is ratiometric: sensitivity and offset vary in direct proportion to supply voltage. 2) Output linearity is not guaranteed within 500mV of the supply rails. 3) Output loading to VDD or VSS must be = 5.1k. Tested with 10k from OUT to VSS.
LEM reserves the right to carry out modifications on its transducers without prior notice.
10 ARMS 15 A VDD * 20 = 100 mV/A 30% 25 A for 15 seconds 5.0 VDC 10% 2500 VRMS for 1 minute within 500 mV of each supply rail = 0.5 to 4.5 V VDD / 2 = 2.5 VDC 12% < 0.8% typical, 1.2% maximum 2.0 mV/K maximum 0.5 % after 45A peak overload 0.20 %/K maximum DC - 16 kHz (-3dB; 10 kHz @ -1dB) 25 s (with 2 - 10 A/s rising or falling edge) -40 to 85 C -55 to 95 C 12 mA max @ 5.5VDC 1 mA source and sink UL Recognized materials meeting UL94-V0 5 grams nominal PCB Footprint (as shown on page 2) A positive going output signal is obtained when the primary current flows from the I+ to I- pin.
LEM U.S.A., INC.
6643 WEST MILL ROAD MILWAUKEE, WI 53218
Page 1 of 2
TEL: 414/ 353-0711 FAX: 414/ 353-0733
030516/01 lus@lem.com http://www.lem.com
C:\aaa\Projects\HTS10P\Rev 01\HTS10P(01).doc 03.05.16 18:11
Dimensions for the HTS 10-P in millimeters
(1mm = 0.0394"):
Notes: A positive going output signal is obtained when the primary current flows from I+ to I-. Primary wires may also be used through the aperture. Sensitivity is reduced by a factor of 3. A positive going output signal is obtained when the primary current flows from bottom to top. Optimum performance is attained with a 0.1F capacitor between VDD and VSS and a 100pF capacitor between OUT to VSS , placed as close to the HTS 10-P pins as possible. Recommended PWB hole diameters: 2 x 1.3 for primary, 3 x 0.8 for secondary. This device is sensitive to electrostatic discharge (ESD) and must be handled appropriately.
LEM reserves the right to carry out modifications on its transducers without prior notice.
LEM U.S.A., INC.
6643 WEST MILL ROAD MILWAUKEE, WI 53218
Page 2 of 2
TEL: 414/ 353-0711 FAX: 414/ 353-0733
030516/01 lus@lem.com http://www.lem.com
C:\aaa\Projects\HTS10P\Rev 01\HTS10P(01).doc 03.05.16 18:11